Air Control valve |
 |
Home>Product Guide Top>Air Control valve |
Solenoid Valve |
|
3, 4-port / Miniature Direct Operated Solenoid Valve for Vacuum & Positive Pressure/ Poppet Seal |
|
|
VA series |
|
・ |
Direct operated / Poppet seal |
・ |
For vacuum and vacuum break control |
・ |
Compact design with 10 mm width /VA01 |
・ |
One coil latch type solenoid |
|
|
|
|
|
Model No. |
Port |
Vacuum Flow
(L/min(ANR) |
Port size |
Mounting |
VA01P□24 |
4 |
- |
M5 |
Sub-base |
VA05P□24 |
- |
Rc1/8 |
VA01PS□23 |
3
(2-position) |
22 |
M5 |
VA01PL□23 |
22 |
VA01PEP34 |
3
(3-position) |
20 |
VA01RDP33 |
10 |
In-line |
|
|
|
|
Pilot/Poppet 3-port Solenoid Valve |
|
|
PV07 PS23 / RS23 series |
|
・ |
Fast response ON/OFF 6ms |
・ |
Compact
Width 11mm PV07PS23 (Sub-base)
Width 15mm PV07RS23 (In-line) |
・ |
Large flow
CV 0.35, 450L/min at 0.5MPa |
|
|
|
|
|
|
|
|
ASV200, ASC500/ASO500, ASV2000, ASV5000,ASV13000,ASV15000 |
|
・ |
The Air Saver can reduce your air consumption by up to 40% over traditional
air blow systems |
・ |
Features an integral valve which enables a pulse blow function. |
・ |
Pulse blow function is more efficient at dust removal. |
・ |
Reduction in plant CO2 emissions. |
・ |
Big contribution to energy-saving activities. |
|
|
|
|
Air Saver Module (Air Saver Unit for air blowgun) |
|
|
HASV08R series |
|
・ |
Air Saver Unit for air blowgun |
・ |
Approx. 35% air consumption reduction |
・ |
Possible to attach visible air blowgun |
・ |
Built-in pulse/continuous blow change over button |
・ |
Blow efficiency up because of pulsed air |
・ |
With pulse frequency adjustment screw |
|
|
|
|
|
|
3, 5-port / Pilot Operated Solenoid Valve / Rubber Seal |
|
|
ADEX VALVE A05, A12, A20 |
|
・ |
Pilot operated / Rubber seal |
・ |
Wide variation |
・ |
Small size / Large flow (Body width remains the same, but the flow rate 1.5 to 3 times more than conventional valves. |
|
|
|
|
|
Model No. |
Port |
Sonic Speed Conductance
dm3/(s・bar) |
Port size |
Mounting |
A05P |
5
(2,3position) |
1.16 |
Rc1/8 |
Sub-base |
A05R |
0.8 |
M5、C4、C6 |
In-line |
A12P |
2.22 |
Rc1/4 |
Sub-base |
A12R |
1.76 |
Rc1/8
C6、C8 |
In-line |
A20P |
4.12 |
Rc1/4、3/8 |
Sub-base |
A20R |
3.52 |
Rc1/4
C8、C10 |
In-line |
A05G |
5
(2,3position) |
1.16 |
Rc1/8 |
Sub-base |
A05F |
0.8 |
M5、C4、C6 |
In-line |
A12G |
2.22 |
Rc1/4 |
Sub-base |
A12F |
1.76 |
Rc1/8
C6、C8 |
In-line |
A20G |
4.12 |
Rc1/4、3/8 |
Sub-base |
A20F |
3.52 |
Rc1/4
C8、C10 |
In-line |
A05E |
5
(2,3position) |
1.16 |
- |
Manifold |
A12E |
0.8 |
- |
|
|
In-Line type solenoid valve |
|
|
ADEX Plus - Obsolete - |
|
・ |
Value price solenoid valve |
・ |
24VDC / 0.6W Low power consumption |
・ |
BSPT, BSPP port thread available |
・ |
Using experienced pilot valve |
|
|
|
|
|
Model No. |
Port |
Vacuum Flow
(L/min(ANR) |
Port size |
Mounting |
P2A05 |
5
(2,3 position) |
0.22 |
M5 |
In-line |
P2A12 |
0.4~0.59 |
Rc1/8 |
P2A20 |
0.65~0.82 |
Rc1/4 |
|
|
|
|
|
|
3, 5-port / Pilot Operated Solenoid Valve / Rubber Seal |
|
|
PC/RC2, 5, 13 series |
|
・ |
Pilot operated / Rubber seal |
・ |
Compact design with 10, 15, 18mm width |
・ |
Flap type solenoid is mounted to assure long life |
|
|
|
|
|
|
5-port / Pilot Operated Solenoid Valve / Rubber Seal |
|
|
PC/RC06, 08, 15 series |
|
・ |
Pilot operated / Rubber seal |
・ |
Control up to 100mm bore cylinders. |
・ |
Different pressures have no effect on the operation of this balanced spool valve. |
|
|
|
|
5-port / Pilot Operated Solenoid Valve / Metal Seal |
|
|
K20 series -Obsolete- |
|
・ |
Pilot operated / Metal seal |
・ |
Excellent for critical application with high protection grade of IP65,
flame resistance plastic material envelop and standard ground terminal
connection. |
・ |
Operate up to 100mm bore cylinder, High pressure model up to 1.6MPa supply pressure available. |
|
|
|
|
3, 5 port / Pilot Operated Solenoid Valve / Metal Seal |
|
|
PM6, 06, 08, 10, 15, 25 series |
|
・ |
Pilot operated / Metal seal |
・ |
Operate up to 200mm bore cylinder. |
・ |
Interface between sub-base and body is common to direct acting solenoid valve, A series. |
・ |
Different pressures have no effect on the operation of this balanced spool
valve. (Only for external pilot type) |
|
|
|
|
3, 5 port / Direct Operated Solenoid Valve / Metal Seal |
|
|
|
A06, 08, 10, 15 series |
|
・ |
Direct operated / Metal seal |
・ |
Control up to 200mm bore cylinder |
・ |
Plug-in solenoid unit assure easy installed or replacement, With large-sized
terminal. |
・ |
Different pressures have no effect on the operation of this balanced spool
valve. |
|
|
|
3 port / Direct Operated Solenoid Valve / Poppet Seal |
|
|
|
SS231 |
|
・ |
Direct operated / Poppet Seal |
・ |
Sub-base Mounting type |
|
|
|
|
|
Ultra Small 3-port Solenoid Valve |
|
|
|
X-Valve series (*) |
|
・ |
2-position, 3-port solenoid valve with just 8mm width. |
・ |
Unitized body incorporates its functional features in a single glass-reinforced,
PBT molded body. |
・ |
Seal material is available from FKM, EPDM and Silicone |
・ |
Operating pressure: 41 to 689kPa (4 series), Voltage: DC3 to 24V |
・ |
Flow rate: 4 L/min(41kPa) to 9 L/min(689kPa) |
|
|
|
|
Small 2-port Solenoid Valve |
|
|
|
Ten-X series (*) |
|
・ |
2-position, 2-port small size solenoid valve |
・ |
Operating pressure: 41kPa, Flow rate: 8 L/min |
・ |
Response time: less than 5ms |
・ |
Low leakage: less than 0.016cc/min |
・ |
Low power consumption type: 0.5W (DC5, 12, 24V) |
・ |
Light construction: 11g |
|
|
|
|
Ultra Small Proportional Solenoid Valve |
|
|
|
VSO series (*) |
|
・ |
Operating pressure: -90kPa to 1.0MPa |
・ |
100 million life cycles, Low leakage: 0.2cm3/min |
・ |
Standout hysteresis feature, Maintains ideal flow through thermal compensation. |
・ |
Oxygen media is available with optional treatment |
|
|
 |
|
MD PRO series (*) |
|
・ |
Standard model of proportional valve |
・ |
10 million life cycles, Low leakage: 0.22cm~3/min |
・ |
Operation pressure: -90kPa to 0.7MPa |
・ |
Oxygen media is available with optional treatment |
・ |
Power consumption: Max. 2W |
|
|
|
|
(*) This item is supplied from Parker in worldwide. Please refer to www.parker.com
in the detail. |
|
|
|
Permanent Stop |
|
・ |
It helps to stop middle position of the stroke for cylinders. |
|
|
|
PageTop  |
 |
 |