3.5MPa Compact Design Hydraulic Cylinder 35S-1RD Series/ Double-acting Double-rod (Switch-Set)
Switch Code
Sectional Drawing
Description of term
Product Lineup Click the icon as follows, to check the details.
Rod End Type Bore Size(mm)
20 25 32 40 50 63
Female 35S-1RD6SD20N10-00 35S-1RD6SD25N10-00 35S-1RD6SD32N10-00 35S-1RD6SD40N10-00 35S-1RD6SD50N10-00 35S-1RD6SD63N10-00
Male 35S-1RD6SD20N10T00 35S-1RD6SD25N10T00 35S-1RD6SD32N10T00 35S-1RD6SD40N10T00 35S-1RD6SD50N10T00 35S-1RD6SD63N10T00

Specifications
Action Style Double-acting Double-rod/Switch Set
Available Bores(mm) 20,25,32,40,50,63
Mounting Style SD
Rod End Type Female/Male
Norminal Pressure 3.5MPa
Max. Allowable Pressure 4MPa
Min. Working Pressure 20/25/32:0.15MPa 40/50/63:0.1MPa
Proof Test Pressure 5MPa
Operating Speed Range 8 to 100mm/s
Operating Temperature
(Ambient / Oil)
AX/AZ : -10 to +70 ºC WR/WS : -10 to +60 ºC(But do not use when frozen)
Cushion Mechanism None
Working Fluid Petroleum-based fluid
(For other working oil, refer to the table of working oil adaptability.)
Thread Tolerance JIS 6H/6g
Stroke Tolerance 0 to 1.0mm
Note)

Hydraulic pressure that is generated in cylinder dur to the inertia of load shall be set at less than the maximum allowable pressure.
The cylinder bosy is not applied to the cutting oil-proof specifications.
This cylinder is not equipped with an air bleeder.
If the piston touches the cylinder end at the stroke end, decelerate the cylinder to a speed lower than the minimum operating speed.

Stroke Fabrication Range
Bore
(mm)
Cylinder Stroke(mm)
5 10 15 20 25 30 35 40 45 50 60 70 80 90 100
20 - - - - -
25 - - - -
32 - -
40
50
63
Note) : Standard manufacturing range : Made-to-order

Switch Mountable Minimum Stroke
Bore With a switch With two switches
AX/AZ WR/WS AX/AZ WR525 WR535 WS235 WS245
Contact Noncontact
20 to 32 5 10 10 15 - - - -
40 to 63 10(5)* 20 10 20 15
Note) The valve in ( ) is show that when 2 switches mounting one by one at different channel by two positions.
Note) Only one switch of type WR and WS is available for bores 20/25/32 mm.2 switches can fit on bore 40/50/63 mm at 2 different positions by different channel. Normally one fitting channel could only for one switch.
Note) There will cause interference when you use 2 contact switches for 10 stroke. Please adjust.
* When you select 2 non-contact switches for bore larger than 40 mm and more than 10 mm stroke, please fit the switches on different channel.


Allowable Fluid, Seal Material
Seal Material Allowable Fluid
Petroleum-based Fluid Water-Glycol Fluid Phosphate-Ester Fluid Water in Oil Fluid Oil in Water Fluid
6:HNBR
Note)

The -marked items are applocable,while the -marked items are inapplicabe.
Consult with us separately in case that Phosphate-Ester Fluid is desired.