Product Lineup |
 Click the icon as follows, to check the details. |
| Bore Size(mm) |
| 32 |
40 |
50 |
63 |
80 |
100 |
125 |
160 |
 |
 |
 |
 |
 |
 |
- |
- |
|
 |
Specifications |
| Action Style |
Double-acting Double-rod/Switch set |
| Available Bores(mm) |
32/ 40/ 50/ 63/ 80/ 100 |
| Mounting Style |
SD/LA/LB/FA/TA/TC |
| Piston Seal |
U-seal |
Slipper seal |
| Norminal Pressure |
3.5MPa |
| Max. Operationg Pressure |
4.5MPa |
| Proof Test Pressure |
5MPa |
| Min. Operating Pressure |
0.2MPa |
| Operating Speed Range |
8 to 300mm/s |
0.1 to 300mm/s |
| Temperature Range |
-10 to +70ºC (But do not use when frozen) |
| Structure of Cushiong |
Metal cushion |
| Recommendable Fluid |
Petroleum-based fluid
(In case the use of other fluids, refer to the table for adaptation of
fluid) |
| Thread Tolerance |
JIS 6g/6H |
| Standard Stroke |
32/ 40:to 1000mm 50/ 63:to 1200mm
80/ 100:to 1600mm 125/ 160:to 1800mm |
| Stroke Tolerance |
 |
| Accessories |
Rod End Attachment |
1Rod end eye(T type)/2Rod end clevis with pin(T type)/F joint(F type) |
| Bracket |
TA/TC bracket |
| Note) |
Hydraulic pressure that is generated in cylinder due to tha inertia of
load shall be set at less than the maximum allowable pressure. |
|
The cylinder body os not applied to the cutting oil-proof specifications. |
|
Conex of boots is the registered trade mark of Teijin,Ltd.. |
|
Slipper seal is the registered trade mark of Japan Bulker Industry Co. |
 |
Min. stroke of switch set cylinder |
Bore Size
(mm) |
Except TC Type |
TC Type |
| 1 switch mounted |
2 switches mounted |
1 switch mounted |
2 switches mounted |
| AX/AZ |
WE/WS |
SR |
AX/AZ |
WE/WS |
SR |
AX/AZ |
WE
/WS |
WE/WS |
AX/AZ |
WE/WS |
SR |
32 |
25 |
55(40) |
35 |
26 |
55(40) |
35 |
55 |
85(70) |
65 |
105 |
165(140) |
130 |
40 |
50 |
63 |
20 |
20 |
80 |
70 |
165(145) |
135 |
100 |
60 |
90(80) |
75 |
110 |
165(150) |
140 |
| note) |
For TC type with 1 switch mounted, it is a cylinder stroke in the case
that TC type attachments are set at those except the center. |
|
For the minimum PH dimension of TC type for mounting switch, refer to the
dimensional drawings of TC types. |
|
Concerning WR/WS, the dimension of ( ) is the minimum stroke in which WR515,
WS225 are available. |

 |
Allowable Fluid, Seal Material |
| Seal Material |
Allowable Fluid |
| Petroleum-based Fluid |
Water-Glycol Fluid |
Phosphate-Ester Fluid |
Water in Oil Fluid |
Oil in Water Fluid |
| 1: Nitrile rubber |
 |
 |
 |
 |
 |
| 3: Fluoric rubber |
 |
 |
 |
 |
 |
| 6: HNBR |
 |
 |
 |
 |
 |
| 8: Slipper seal |
 |
 |
 |
 |
 |
| Note1) |
The and -marked items are applicable, while the -marked items are inapplicable. |
| Note2) |
The -marked items are the recommended packing materials in case of giving
the first priority to abrasion resistance. |
| Note3) |