16MPa Compact Design Hydraulic Cylinder 160S-1RD Series/ Double-acting Double-rod (Switch-Set)
Switch Code
Sectional Drawing
Description of Term
Product Lineup Click the icon as follows, then the price and
Mounting Style Rod End Type Bore(mm)
20 25 32 40 50 63 80 100 125
SD Female - - 160S-1RD6SD32N10-00 160S-1RD6SD40N10-00 160S-1RD6SD50N10-00 160S-1RD6SD63N10-00 160S-1RD6SD80N10-00 - -
Male - - 160S-1RD6SD32N10T00 160S-1RD6SD40N10T00 160S-1RD6SD50N10T00 160S-1RD6SD63N10T00 160S-1RD6SD80N10T00 - -
LD/FA Female - - 160S-1RD6LD32N10-00 160S-1RD6LD40N10-00 160S-1RD6LD50N10-00 160S-1RD6LD63N10-00 160S-1RD6LD80N10-00 - -
Male - - 160S-1RD6LD32N10T00 160S-1RD6LD40N10T00 160S-1RD6LD50N10T00 160S-1RD6LD63N10T00 160S-1RD6LD80N10T00 - -

Specifications
Action Style Double-acting Double-rod/Switch set
Available Bores(mm) 32/40/50/63/80
Mounting Style SD/LA/LD/FA
Rod End Type Female/Male
Norminal Pressure 16MPa
Max. Allowable Pressure 16MPa
Proof Test Pressure 24MPa
Min. Working Pressure 0.3MPa
Operating Speed Range 8 to 100mm/s
Operating Temperature
(Ambient Temperature and Oil Temperature)
-10 to +120 ºC(But do not use when frozen)
Structure of Cushioning None
Working Fluid Petroleum-based fluid
(For other working oil, refer to the tableof working oil adaptability.)
Thread Tolerance JIS 6H/6g
Stroke Tolerance 0 to 0.8mm
Note) Hydraulic pressure that is generated in cylinder dur to the inertia of load shall be set at less than the maximum allowable pressure.
This cylinder is not equipped with an air bleeder.
Since lateral load (eccentric load) cannot be applied to the piston rod, carefully adjust it after rod end attachment.
If the piston touches the cylinder end at the stroke end, decelerate the cylinder to a speed lower than the minimum operating speed.ピ

Stroke Fabrication Range
Bore
(mm))
Cylinder Stroke(mm)
5 10 15 20 25 30 35 40 45 50 60 70 80 90 100
32
40
50
63
80
Note1) :Range available for manufacturing for order

Switch Mountable Minimum Stroke
Bore
(mm
)
1switch mounted 2 switches mounted
AX/AZ WR WS AX/AZ WR WS
32 5 5 10 10 10 20
40
50
63
80
Note1) When attaching two swithces of the WR or WS type, they cannot be attached to the same surfice.(WR and WD type switches are not available for LA mounting.)
There may cause interference with switch. Please adjust when one contact switch is used in the case of 10mm stroke.
Please use two locations on the switch mounting channel when the no-contact switch is used in the case of 10mm stroke.

Allowable Fluid, Seal Material
Seal Material Allowable Fluid
Petroleum-based Fluid Watar-Glycol Fluid Phoshate-Ester Fluid Water in Oil Fluid Oil in Water Fluid
3: Fluoric rubber
6: HNBR
Note) The and -marked items are applicable, while -marked items are inapplicable
The -marked items are the recommended packing materials in case of the first priority to abrasion resistance.

Copyright(c)2004 TAIYO,LTD. All rights reserved.