14MPa Hydraulic Cylinder 140HW-8R Series(Cutting oil proof)/ Double-acting Single-rod (Switch-Set)
Switch Code
Sectional Drawing
Description of Term
Product Lineup Click the icon as follows, to check the details.
Rod Diameter Bore(mm)
32 40 50 63 80 100 125 140 150 160 180 200 224 250
B 140HW-8R1SD32BB100-AB00 140HW-8R1SD40BB100-AB00 140HW-8R1SD50BB100-AB00 140HW-8R1SD63BB100-AB00 140HW-8R1SD80BB100-AB00 140HW-8R1SD100BB100-AB00 140HW-8R1SD125BB100-AB00 - - - - - - -
C - 140HW-8R1SD40CB100-AB00 140HW-8R1SD50CB100-AB00 140HW-8R1SD63CB100-AB00 140HW-8R1SD80CB100-AB00 140HW-8R1SD100CB100-AB00 140HW-8R1SD125CB100-AB00 - - - - - - -

Specifications
Action Style Cutting fluid proof type/Doubl-acting Single-rod/Swich set
Available bores(mm) 32/40/50/63/80/100/125
Mounting Style SD/LA/LB/LC/FA/FB/FY/FZ/FC/FD/FK/CA/CS/CB/TA/TC
Rod Dia. Type B C
Norminal Pressure 14MPa
Max. Allowable Pressure Rod Side 18MPa 14MPa
Head Side 18MPa
Proof Test Pressure 21MPa
Min. Working Pressure Rod Side 0.45MPa 0.4MPa
Head side 0.3MPa
Operating Speed Reange 32 to 63:8 to 400mm/s 80 to 125:8 to 300mm/s
Operating Temperature -10 to +80 ºC(But, do not use when frozen)
Structure of Cushioning Metal cushion
Working Fluid Petroleum-based fluid
(In case of the use of other fluids, refer to the table for adaptation of fluids.)
Thread Tolerance JIS 6g/6H
Standard Stroke 32 to 50: to 1200mm 63/80: to 1600mm 100/125: to 2000mm
Stroke Tolerance
Accessories Rod End Attachment 1Rod End Eye(T type)/1Rod End Spherical Eye(S type)/
2Rod End Clevis(T Type)/F Jpoint(F type)
Boots Standard:Nylon tarpaulin Semi-standard:Chloroprene/Conex
Note) Hydraulic pressure that is generated in cylinder due to the inertia of load shall be set at less than the maximum allowable pressure.
Conex of boots is the generated trade mark of Teijin,Ltd.

Min. stroke of switch set cylinder
Bore Size
mm
Except TC Type TC Type
1 switch mounted 2 switches mounted 1switch mounted 2 switches mounted
AX
AX205W
WR WS AX
AX205W
WR WS AX
AX205W
WR WS AX
AX205W
WR WS
32 20 45(35) 45(35) 25 45(35) 45(35) 50 70(60) 75(65) 110 155(135) 165(145)
40 115
50 40(30) 45(35) 40(30) 45(35)
63 40(30) 40(30) 85(75) 85(75) 125 170(150) 175(155)
80 130
100 35(25) 40(30) 35(25) 40(30) 65 95(85) 135 175(150) 190(170)
125 40(25) 40(25) 70 90(80) 150 185(160) 195(170)
140 - - - - 95 - - 175 - -
Note) For TC type with 1 switch mounted, it is a cylinder stroke in the case that TC type attachments are set at those except the center.
For the minimum PH dimension of TC type for mounting switch, refer to the dimensional drawing of TC type.
Concerning WR/WS, the dimension of ( ) is the minimum stroke in which WR515, WS225 are available.


Allowable Fluid, Seal Material
Seal Material Allowable Fluid Aqueous Cutting Oil
Petroleum-based Fluid Water-Glycol Fluid
6: HNBR

Copyright(c)2004 TAIYO,LTD. All rights reserved.