Product Lineup |
 Click the icon as follows, to check the details. |
|
| Type |
Mounting Style |
Available Bores(mm) |
| 12 |
16 |
20 |
25 |
32 |
40 |
50 |
63 |
| Standard Type |
SD |
- |
- |
- |
 |
- |
 |
 |
 |
| LB |
- |
- |
- |
 |
- |
 |
 |
 |
| FA |
- |
- |
- |
 |
- |
 |
 |
 |
| TA |
- |
- |
- |
 |
- |
 |
 |
 |
|
|
 |
Specifications |
| Action Style |
Non-rotating Type/Double-acting Double-rod/Standard Type with Switch |
| Aailable Bores(mm) |
25, 40, 50, 63 |
| Mounting Style |
SD,LB,FA,TA,TA with B,AD,BD |
| Fluid Used |
Air |
| Lubrication |
Not necessary(But possible) |
| Operating Pressure Range |
25, 40:0.1 to 1MPa 50, 63:0.05 to 1MPa |
| Proof Test Pressure |
1.5MPa |
| Note1)Operating Speed Range |
50 to 700mm/s |
| Operating Temperature |
-10 to +70 ºC(But do not use when frozen) |
| Cushion Mechanism |
25, 40: With Cushion Pad 50, 63: With Cushion on Both Ends |
| Rotating Angle Tolerance |
25: 1.5 Degrees 40: 1 Degree 50, 63: 0.8 Degrees |
| Allowable Torque |
25: less than 0.49N,m 40: less than 0.96N,m 50, 63: less than 3.4N,m |
| Thread Tolerance |
JIS 6g/6H |
| Stroke Tolerance |
 |
| Accessories |
Rod End Attachment |
Rod End Spherical Eye(S type)/Rod End Eye(T type)/Rod End Clevis(Y type)(Y
Type 50, 63) |
| Bracket |
TA |
| Dust Cover |
Nylon tarpaulin |
| Note1) |
When setting a switch in the intermediate position, set the cylinder speed to
300mm/s max. in consideration of the response speed of load relay and others. |
| Note2) |
Consult with us separately in case that the port position and cushion valve
position are modified. |
 |
Stroke Fabrication Range |
|
Bore
(mm) |
Cylimder Stroke(mm) |
Stroke Limit |
| 015 |
025 |
030 |
050 |
075 |
100 |
125 |
150 |
175 |
200 |
250 |
300 |
350 |
400 |
450 |
500 |
25 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
- |
- |
- |
- |
450 |
40 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
- |
- |
- |
- |
450 |
50 |
- |
 |
- |
 |
 |
 |
- |
 |
- |
 |
 |
 |
- |
- |
- |
- |
450 |
63 |
- |
 |
- |
 |
 |
 |
- |
 |
- |
 |
 |
 |
- |
- |
- |
- |
450 |
| Note1) |
Consult with us separately in case that stroke other than above
standard stroke (marked with )is desired. |
|
|
|
|
|