10MPa Compact Design Hydraulic Cylinder 100S-1R Series/ Double-acting Single-rod (Switch-Set)
Switch Code
Sectional Drawing
Description of term
Product Lineup
Mounting Style Rod End Type Bore(mm)
20 25 32 40 50 63 80 100
SD Femal 100S-1R6SD20N10-00 100S-1R6SD25N10-00 100S-1R6SD32N10-00 100S-1R6SD40N10-00 100S-1R6SD50N10-00 100S-1R6SD80N10-00 100S-1R6SD100N10-00
Male 100S-1R6SD20N10T00 100S-1R6SD25N10T00 100S-1R6SD32N10T00 100S-1R6SD40N10T00 100S-1R6SD50N10T00 100S-1R6SD63N10T00 100S-1R6SD80N10T00 100S-1R6SD100N10T00
LD/FA/FB Female 100S-1R6LD20N10-00 100S-1R6LD25N10-00 100S-1R6LD32N10-00 100S-1R6LD40N10-00 100S-1R6LD50N10-00 100S-1R6LD63N10-00 100S-1R6LD80N10-00 100S-1R6LD100N10-00
Male 100S-1R6LD20N10T00 100S-1R6LD25N10T00 100S-1R6LD32N10T00 100S-1R6LD40N10T00 100S-1R6LD50N10T00 100S-1R6LD63N10T00 100S-1R6LD80N10T00 100S-1R6LD100N10T00

Specifications
Action Style Double-acting Singble-rod/Switch Set
Available Bores(mm) 20,25,32,40,50,63,80,100
Mounting Style SD/LD/FA/FB
Rod End Type Female/Male
Norminal Pressure 10MPa
Max. Allowable Pressure 16MPa(Refer to the operating pressure range )
Proof Test Pressure 20MPa
Min. Working Pressure 0.3MPa
Operating Speed Range 8 to 100mm/s
Operating Temperature
(Ambient / Oil)
AX/AZ : -10 to +70 ºC WR/WS : -10 to +60 ºC(But do not use when frozen)
Cushion Mechanism None
Working Fluid Petroleum-based fluid
(For other working oil, refer to the table of working oil adaptability.)
Thread Tolerance JIS 6H/6g
Stroke Tolerance 0 to 0.8mm
Note)

Hydraulic pressure that is generated in cylinder dur to the inertia of load shall be set at less than the maximum allowable pressure.
This cylinder is not equipped with an air bleeder.
Do not apply horizontal load (Eccentric load) to the piston rod. Please mounting it with caution.

Stroke Fabrication Range
Bore
(mm)
Cylinder Stroke(mm)
5 10 15 20 25 30 35 40 45 50 60 70 80 90 100
20 - - - - -
25 - - - - -
32
40
50
63
80
100
Note1) : Standard manufacturing range :Made-to-order

Switch Mountable Minimum Stroke
Bore
(mm)
With a switch With two switches
AX/AZ T WR WS AX/AZ T WR WS
20 - 5 - - - 10 - -
25
32 5 - 5 10 10* - 10 20
40
50
63
80
100 15
Note1) When you use 2 contact switches of type WR and WS, you can not mount them on the same surface.
There will cause interference when you use 2 contact switches for 10 stroke. Please adjust.
* When you select 2 non-contact switches of type AX and AZ at 10 stroke, please fit the switches on different channel.

Allowable Fluid, Seal Material
Seal Material Allowable Fluid
Petroleum-based Fluid Water-Glycol Fluid Phosphate-Ester Fluid Water in Oil Fluid Oil in Water Fluid
3:Fluoric rubber
6:HNBR
Note) The -marked items are applocable,while the -marked items are inapplicabe.
The -marked items are the recommended packing materials in case of giving the first priority to abrasion resistance.

Copyright(c)2004 TAIYO,LTD. All rights reserved.