Port Size:Rc3/4·Rc1 |
|
 |
| Filter regulator and lubricator combination is what must be necessary for pneumatic system. It utilize for compressed air cleaning, pressure adjustment and supply the lubricant oil to the pneumatic equipments. |
 |
Light weight and compact designed by newly-unified smart square type. |
 |
Combination can simply joint with joinery method. |
 |
Casing is easy to remove for maintenance by adopting one-touch clamp. |
 |
Lubrication can work without stopping main pressure. |
|
 |
 |
Specifications |
 Click the icon as follows, to check the details. |
|
| Model Number |
HFRL-20- |
HFRL-25- |
| Port Size |
Rc3/4 |
Rc 1 |
| Working Fluid |
Air |
| Max. Working Pressure |
1MPa |
| Setting Pressure Range |
0.05∼0.9MPa |
| Proof Test Pressure |
1.6MPa |
| Temperature Range |
0∼+50ºC(But do not use when frozen) |
| Filter Element |
Standard: 30 m ; Seme-standard: 5 m |
| Storage Volume of Drain |
500cm3 |
| Oil Container Vol. |
500cm3 |
| Drain Method |
Standard:One-touch type manual drain ; Seme-standard: Float type auto drain |
| Min. Flow of Oil Drops |
85 /min(ANR) |
| Recommanded Lubricant Oil |
Turbine oil first-class (additive free) equivalent of ISO VG32 |
| Mass |
Manual drain:5.7kg (5.75kg) |
This is the flow when turbine oil dropped 5 drops/min. while pressure (Primary pressure) set at 0.5MPa.
Note) The minimum working pressure of differential pressure type auto drain is 0.1MPa, and minimum working pressure is 0.05MPa.
Note) The value at ( ) is the mass with auto drain. |
Combination Models |
|
| Model |
Combination Models |
Accessories |
| Air Filter |
Regulator |
Lubricator |
Bracket |
| HFRL08 |
HAF-20 |
HRV-20 |
HAL-20 |
HO-B |
| HFRL15 |
HAF-25 |
HRV-25 |
HAL-25 |
|
|
|