Show the Hydraulic Equipment list. Pneumatic Equipment
Download PDF Catalogs Catalogs
Download CAD File CAD
Download PDF Instruction Manual Instruction Manual
Send Inquiries to... Inquiry



Equivalent to UL94 V-0, strength in automatic fire extinguishing and will not burn away.
Superior in flexibility with single layer structures.

     
   
Product Lineup Click the icon as follows, to check the details.
Tube
(External dia.× Internal dia.)
Tube Length Tube Color
Black
Omit
White
W
Red
R
Blue
B
Green
G
Yellow
Y
4×2.5 20m FS-4X2-20 FS-4X2-20W FS-4X2-20R FS-4X2-20B FS-4X2-20G FS-4X2-20Y
6×4 20m FS-6X4-20 FS-6X4-20W FS-6X4-20R FS-6X4-20B FS-6X4-20G FS-6X4-20Y
8×5 20m FS-8X5-20 FS-8X5-20W FS-8X5-20R FS-8X5-20B FS-8X5-20G FS-8X5-20Y
10×6.5 20m FS-10X6.5-20 FS-10X6.5-20W FS-10X6.5-20R FS-10X6.5-20B FS-10X6.5-20G FS-10X6.5-20Y
12×8 20m FS-12X8-20 FS-12X8-20W FS-12X8-20R FS-12X8-20B FS-12X8-20G FS-12X8-20Y
Product Lineup
Model FS-4X2.5 FS-6X4 FS-8X5 FS-10X6.5 FS-12X8
External dia. mm 4 6 8 10 12
Internal dia. mm 2.5 4 5 6.5 8
Operating Pressure Range MPa Work out in the curve of rate of change between working temperature and max. working pressure.
Note2)
Max. Working Pressure
(at20ºC)
1.0MPa 1.0MPa 1.2MPa 1.0MPa 1.0MPa
Min. bend radius 10mm 15mm 15mm 20mm 30mm
Working Fluid Air·Water·General fluid
Temperature Range Air:-40∼+80ºC Water:0∼+70ºC General fluid:-40∼+80ºC
(But do not use when frozen)
Material Thermoplastic elastomer
Tube Color Standard: Black·Order-made:White·Red·Blue·Yellow·Green
Mass 10g/m 21g/m 40g/m 60g/m 82g/m
Sales Unit 20m
Note1)

In the case of Water·General fluid, please notice that the surge pressure should be within the Operating Pressure Range.
Note2) In the case of air, maximum 1.0MPa.