Show the Hydraulic Equipment list. Shock Absorber
Download PDF Catalogs Catalogs
Download CAD File CAD
Download PDF Instruction Manual Instruction Manual
Send Inquiries to... Inquiry
Adjustment unnecessary with small, lightweight ; load corresponding type shock absorber of outer dia. M36 screw type.
According to load, the impact object is stopped softly.


With the mounting thread provided on the outer surface of body, the handling is easy as if bolt is mounted.


In case of similar impact loads, the parallel use of over 2 MINI-SOFTERS is available.


There are a plenty of types...with cap that prevents the noise in the impact and with switch that signal is taken at stroke end.
As the structure is simple and solid, MINI-SOFTER body can be used as stopper.

Dimensional Drawings     
   
Product Lineup Click the Model Numbers as follows, to check the details.
Model Numbers Mounting Style
SD FA FB LA
Standard  F3M36N040SD  F3M36N040FA  F3M36N040FB  F3M36N040LA
With Cap  F3M36S040SD-C  F3M36S040FA-C  F3M36S040FB-C  F3M36S040LA-C
With Switch  F3M36S040SD-JA  F3M36S040FA-JA  F3M36S040FB-JA  F3M36S040LA-JA
 F3M36S040SD-JB  F3M36S040FA-JB  F3M36S040FB-JB  F3M36S040LA-JB
 F3M36S040SD-JC  F3M36S040FA-JC  F3M36S040FB-JC  F3M36S040LA-JC
 F3M36S040SD-JD  F3M36S040FA-JD  F3M36S040FB-JD  F3M36S040LA-JD
Specifications
Model Numbers Standard With Cap
Mounting Style SD,FA,FB,LA
Max. energy absorption 353J
Stroke 40mm
Note1)Max. Energy Capacity Per Min. 1410kg
Propulsion Range 127 to 4900N
Impact Object Weight Range less than 1000kg
Impact Speed Range 0.1 to 2.0m/s
Note2)Max. Resisting Force Value 23700N
Note2)Rod Return Force 44.6 to 85.3N
Rod Return Time 0.4s
Max. Operating Cycle 60 cycle/min
Operating Temperature Range -5 to +70 Celsius Degree/With Switch : -5 to +50 Celsius Degree(But do not use when frozen)
Weight Body 1.054kg 1.160kg
Mounting Attachment FA nut : 0.399kg FB nut : 0.621kg LA nut : 0.369kg With Switch : 0.476kg
Note1) Max. energy capacity per minute in the table is shown at the ambient temperature of 26.7 Celsius degree. Max. energy capacity per minute at the ambient temperature T (Celsius degree) mentioned as E2(J/min) is calculated according to following formula.
Note2) It indicates the max. value when stroke 40mm is pushed.