Show the Hydraulic Equipment list. Shock Absorber
Download PDF Catalogs Catalogs
Download CAD File CAD
Download PDF Instruction Manual Instruction Manual
Send Inquiries to... Inquiry
Adjustment unnecessary with small, lightweight ; load corresponding type shock absorber of outer dia. M25 screw type.
According to load, the impact object is stopped softly.


With the mounting thread provided on the outer surface of body, the handling is easy as if bolt is mounted.


In case of similar impact loads, the parallel use of over 2 MINI-SOFTERS is available.


There are a plenty of types, with cap that prevents the noise in the impact and with switch that signal is taken at stroke end.
As the structure is simple and solid, MINI-SOFTER body can be used as stopper.

 Dimensional Drawings    
   
Product Lineup Click the Model Numbers as follows, to check the details.
Model Numbers Mounting Style
SD FA FB LA
Standard  F3M25N025SD  F3M25N025FA  F3M25N025FB  F3M25N025LA
With Cap  F3M25S025SD-C  F3M25S025FA-C  F3M25S025FB-C  F3M25S025LA-C
With Switch  F3M25S025SD-JA  F3M25S025FA-JA  F3M25S025FB-JA  F3M25S025LA-JA
 F3M25S025SD-JB  F3M25S025FA-JB  F3M25S025FB-JB  F3M25S025LA-JB
 F3M25S025SD-JC  F3M25S025FA-JC  F3M25S025FB-JC  F3M25S025LA-JC
 F3M25S025SD-JD  F3M25S025FA-JD  F3M25S025FB-JD  F3M25S025LA-JD
Specifications
Model Numbers Standard With Cap
Mounting Style SD,FA,FB,LA
Max. energy absorption 98.1J
Stroke 25mm
Note1)Max. Energy Capacity Per Min. 745kg
Propulsion Range 88.3 to 2500N
Impact Object Weight Range less than 510kg
Impact Speed Range 0.1 to 2.0m/s
Max. Resisting Force Value 11700N
Note2)Rod Return Force 27.9 to 58.4N
Note2)Rod Return Time 0.3s
Max. Operating Cycle 60 cycle/min
Operating Temperature Range -5 to +70Celsius Degree(With Switch : -5 to +50Celsius Degree)(But do not use when frozen)
Weight Body 0.381kg 0.425kg
Mounting Attachment FA nut : 0.129kg FB nut : 0.226kg LA nut : 0.243kg With Switch : 0219kg
Note1) Max. energy capacity per minute in the table is shown at the ambient temperature of 26.7 Celsius degree. Max. energy capacity per minute at the ambient temperature T (Celsius degree) mentioned as E2(J/min) is calculated according to following formula.
Note2) It indicates the max. value whrn stroke 25mm is pushed.