Show the Hydraulic Equipment list. Shock Absorber
Download PDF Catalogs Catalogs
Download CAD File CAD
Download PDF Instruction Manual Instruction Manual
Send Inquiries to... Inquiry

Multi-aperture orifice
As compared with the 06 series, it is a size large type. With the change of moving load energy, it is ideal for of comparatively large energy capacity.


As it is the variable orifice type, the equivalent load is in the range set for each type. And if it is in the max. energy range, the non-phase adjustment is available.


The economical shock absorber can be selected with the smaller resisting force than the single aperture orifice by adjusting correctly.


To cope with the fluctuation of actual equivalent load, it is designed for the wide range of adjustment.

 Dimensional Drawings    
   
Specifications Click the Model Numbers as follows, to check the details.
Model Numbers F ASF-11-20 ASF-11-30 ASF-11-40
E ASE-11-20 ASE-11-30 ASE-11-40
U ASU-11-20 ASU-11-30 ASU-11-40
Mounting Style E,F,U
Max. energy absorption 677J 1010J 1350J
Stroke 50.8mm 76.2mm 101.6mm
Equivalent Weight Range 22 to 22000kg
Note1)Max. Energy Capacity Per Min. 3920J/min 4610J/min 5360J/min
Impact Speed Range 7.6m/s
Note3)Max. Resisting Force Value 27100N
Note2)Rod Return Force 180N 159N 176N
Note2)Rod Return Time 0.1s 0.2s 0.3s
Max. Operating Cycle 30 cycle/min
Operating Temperature Range -5 to +50 Celsius Degree(But do not use when frozen)
Weight F 6.36kg 7.66kg 8.87kg
E 6.8kg 8.11kg 9.36kg
U 5.46kg 8.56kg 9.77kg
Accessories Auxiliary oil tank
Note1) Max. energy capacity per minute in the table is shown at the ambient temperature of 26.7 Celsius degree. Max. energy capacity per minute at the ambient temperature T (Celsius degree) mentioned as E2(J/min) is calculated according to following formula.
Note2) It indicates the max. value when full stroke is pushed.
Note3) Max. resisting force value is the value in case that appropriate adjustment has been conducted.

Accessories Click the Model Numbers as follows, to check the details.
Product Name Model Numbers Model Numbers
Auxiliary oil tank OT-05H-A OT-05V-A
The regular shock absorption is not available if working fluids decrease or the air is mixed. For the appropriate supply of working fluids, it is necessary to mount the auxiliary oil tank. The tank shall be used in case that it is used over once per minute.

Change Parts Click the Model Numbers as follows, to check the details.
Product Name Capacity Model Numbers
Working Fluids 0.25 liters SA-OIL025
0.5 iters SA-OIL05
1 liter SA-OIL1

Copyright(c)2004 TAIYO,LTD. All rights reserved.